氫氧化鉀時(shí)固體產(chǎn)品,在某些特殊行業(yè)中需要配制氫氧化鉀溶液。配制溶液是個(gè)技術(shù)活,需要對(duì)化學(xué)產(chǎn)品有很深的了解并熟練操作實(shí)驗(yàn)儀器,本文以配制標(biāo)準(zhǔn)溶液濃度為例,詳細(xì)介紹:
Potassium hydroxide is a solid product, which needs to prepare potassium hydroxide solution in some special industries. Preparation of solution is a technical activity, which requires a deep understanding of chemical products and skilled operation of experimental instruments
1、氫氧化鉀基準(zhǔn)物經(jīng)干燥處理并恒重,純度符合要求。
1. After drying and constant weight, the purity of potassium hydroxide reference material meets the requirements.
2、天平須經(jīng)過檢定且處于水平狀態(tài)。
2. The balance must be calibrated and level.
3、稱取的基準(zhǔn)物的量要準(zhǔn)確,稱取0.27—0.33g,稱準(zhǔn)0.0001g,基準(zhǔn)物不能灑落稱量瓶或三角燒瓶外,影響重量。
3. The weight of the reference substance should be accurate, weighing 0.27-0.33g to 0.0001g. The reference substance should not fall outside the weighing bottle or triangular flask, affecting the weight.
4、所用蒸餾水須符合GB6682中三級(jí)水標(biāo)準(zhǔn),煮沸10分鐘,去除CO2。
4. The distilled water used must meet the third grade water standard in gb6682, and be boiled for 10 minutes to remove CO2.
5、蒸餾水加入80ml,搖動(dòng),使其充分溶解。
5. Add 80 ml distilled water and shake to make it dissolve completely.
6、標(biāo)定過程中所用量筒、三角燒瓶須潔凈干燥,量筒、滴定管經(jīng)檢定。
6. The measuring cylinder and triangular flask used in the calibration process shall be clean and dry, and the measuring cylinder and burette shall be verified.
7、所用指示劑要符合要求,為10g/L酚酞指示劑,加入量要準(zhǔn)確。
7. The indicator used should meet the requirements, be 10g / L phenolphthalein indicator, and the addition amount should be accurate.
8、滴定管要用待標(biāo)定氫氧化鉀溶液清洗2—3遍,保證溶液的濃度不受影響。
8. The burette should be cleaned with potassium hydroxide solution to be calibrated for 2-3 times to ensure that the concentration of the solution is not affected.
9、溶液裝入滴定管中須無氣泡,否則影響讀數(shù)體積,手不得拿滴定管有液體位置,以免由于手溫影響體積。
9. There must be no bubbles when the solution is put into the burette, otherwise the reading volume will be affected. Do not hold the burette with liquid position, so as not to affect the volume due to hand temperature.
10、零位調(diào)整或滴定后讀數(shù)須等待30—45s?,且滴定管應(yīng)垂直,視線與滴定管內(nèi)液面處于同一水平位置,讀數(shù)要準(zhǔn)確。
10. Wait 30-45s after zero adjustment or titration?, And the burette should be vertical, the line of sight and the liquid level in the burette should be in the same horizontal position, and the reading should be accurate.
11、終點(diǎn)顏色判斷須準(zhǔn)確,同時(shí)作空白試驗(yàn),系統(tǒng)誤差。
11. At the same time, the blank test should be done to eliminate the systematic error.
12、滴定完畢,根據(jù)計(jì)算公式CKOH=m/[(V1-V0)*0.2042]進(jìn)行計(jì)算,少取三次標(biāo)定結(jié)果的算術(shù)平均值作為標(biāo)準(zhǔn)滴定溶液的實(shí)際濃度,濃度值取四位有效數(shù)字。
12. After titration, calculate according to the calculation formula ckoh = m / [(v1-v0) * 0.2042], take the arithmetic mean of at least three calibration results as the actual concentration of standard titration solution, and take four significant figures as the concentration value.
氫氧化鉀標(biāo)準(zhǔn)溶液配制后需要進(jìn)行反復(fù)測(cè)量,濃度的變化對(duì)產(chǎn)品的性能有很大影響,因此要格外注意。
Potassium hydroxide standard solution needs to be measured repeatedly after preparation. The change of concentration has a great influence on the performance of the product, so special attention should be paid to it.